Head of Wall Joints & Expansion Joints Fire Protection

  • Home
  • Head of Wall Joints & Expansion Joints Fire Protection
Shape Image
ShapeFirestop & Passive Fire Protection Services

MANYCON CONTRACTING COMPANY – Saudi Arabia

!

Advanced Firestop Solutions for Head-of-Wall Joints, Expansion Joints & Wall-to-Floor Interfaces

Manycon Contracting Company – Saudi Arabia offers expert installation of Top/Head of Wall Firestop Systems, designed to seal linear gaps between non-loadbearing walls and structural slabs or roof assemblies. Our firestop solutions are fully compliant with Saudi Civil Defense, UL, and ASTM standards, providing critical compartmentation in commercial, residential, and industrial buildings across Riyadh, Jeddah, Dammam, Khobar, and beyond. We ensure life safety by stopping fire and smoke from traveling through unsealed construction joints—one of the most vulnerable pathways in a fire scenario.

Stuff and spray joint
TOP WALL
!

What is a Top of Wall Firestop System?

A Top of Wall Firestop System seals the gap between a fire-rated wall (gypsum, block, or concrete) and the structural element above (concrete slab or roof deck). These gaps, if left unprotected, become channels for rapid fire and smoke spread. Our firestop systems maintain required fire-resistance ratings (1–3 hours) while allowing for building movement, thermal expansion, and seismic flexibility.

🔧 Our Top/Head of Wall Firestop Services in Saudi Arabia Include:

  1. Firestop for Gypsum & Masonry Wall to Slab Joints
    Installation of fire-resistive joint systems between drywall/block walls and concrete decks using intumescent sealants and fire-rated backing.
  2. Perimeter Joint Fire Containment Systems
    Sealing slab-edge joints behind curtain walls for exterior perimeter protection in high-rise buildings.
  3. Dynamic Joint Firestop Installation
    Flexible firestop systems for joints subject to seismic movement, thermal cycling, or structural vibration.
  4. UL-Classified Head-of-Wall Assemblies
    Application of tested systems using materials from Hilti, 3M, and other approved brands, with full compliance tagging and system documentation.
  5. Inspection, Tagging & Civil Defense Documentation
    Post-installation inspection, joint tagging, and preparation of full reports for submission to Saudi Civil Defense for project approvals.

 

📐 Technical Details of Top/Head of Wall Firestop Systems

🔸 Firestop Materials Used:
Intumescent Sealants & Sprays
Mineral Wool Fire Batts (Compression Fills)
Elastomeric Joint Sealants (Movement Capable)
Backing Rods and Bond Breakers
Firestop Tapes and Brushes (as needed)

🔸 Compliance & Standards:
UL 2079 – Standard for Fire Resistance of Building Joint Systems
ASTM E1966 & E1399 – Joint Systems with Movement Capability
EN 1366-4 – Linear Joint Fire Resistance
Saudi Civil Defense Regulations
NFPA 101 – Life Safety Code Compliance

🔸 Installation Best Practices:
• Full joint cleaning and preparation before sealant application
• Use of backer materials with compression fit
• Consistent depth and width of sealant as per UL design
• Visual inspection, testing, and compliance marking
• Photographic documentation and report generation

🏢 Applications Across Sectors in Saudi Arabia:
• Hospitals & Medical Facilities (OTs, Isolation Zones)
• High-Rise Towers & Mixed-Use Buildings
• Commercial Offices & Shopping Malls
• Airports & Transportation Hubs
• Industrial Facilities & Warehouses
• Government Buildings & Public Utilities

🚀 Why Manycon Saudi Arabia for Top/Head of Wall Firestop Systems?


Civil Defense-Approved Passive Fire Protection Specialist
Trained Teams Using UL-Listed, Tested Assemblies
Expertise in Seismic and Static Joint Applications
Detailed Documentation for Code Compliance & Inspections
Integrated Firestopping, Duct Fireproofing & Compartmentation Services