FM200 Integrity Testing

  • Home
  • FM200 Integrity Testing
Shape Image
Shape FM200 Room Integrity Testing in Saudi

MANYCON TRADING AND CONTRACTING COMPANY – Saudi

!

✅ QCD-Compliant FM200 Room Sealing & Integrity Testing Services in Saudi

MANYCON TRADING AND CONTRACTING delivers trusted FM200 room integrity testing services in Saudi, supporting critical facilities like oil & gas control rooms, telecom infrastructure, data centers, financial institutions, and server rooms to ensure high gas retention and fire safety performance. We conduct airtightness tests, clean agent room compliance checks, and gas suppression system pressure testing across industrial hubs such as Ras Laffan, Lusail, Doha, and other key zones. Our team specializes in room integrity tests for Inergen, FM200, and Novec 1230 systems, helping facilities comply with international fire suppression standards including NFPA 2001, ISO 14520, and QCD regulations.

Clearway Room Integrity Testing 800x533 Photoroo
room integrity testing 2 Photoroo
!

What is FM200 Room Integrity Testing?

According to NFPA 2001, the clean agent must remain in the protected area for a minimum of 10 minutes at or above the extinguishing concentration. A room integrity test measures how long a clean agent like FM200 can remain in an enclosed area to suppress a fire effectively. At Manycon, we conduct FM200 retention time testing using a blower door fan test — a non-invasive method that simulates a discharge scenario without releasing the actual gas. This ensures your FM200 system is compliant without disruption.

Our FM200 Room Testing & Compliance Services in Saudi Include:

  • 01. Room Integrity Fan Test for FM200 Systems

    We perform blower door air tightness tests to measure leakage rates, pressure decay, and agent hold time, ensuring room integrity for FM200 and Novec systems.

  • 02. Room Sealing & Rectification Services

    We identify and seal gas leakage points using fire-rated foams, acoustic sealants, and gap fillers, ensuring compliance with QCD and NFPA room integrity test standards.

  • 03. Retention Time & Pressure Decay Analysis

    Our team calculates and reports the 10-minute hold time using software-simulated testing per NFPA 2001 and ISO 14520 guidelines. We also conduct gas suppression room tightness evaluations for improved performance.

  • 04. QCD-Certified Documentation & Labeling

    We issue QCD-approved FM200 test certificates, test result sheets, labeled tags, and photographic documentation to support your civil defense approval process.

  • 05. Annual Room Retesting & Maintenance Support

    We provide annual FM200 room pressure tests, maintenance audits, and scheduled inspections for continuous compliance across the GCC, including Saudi ,Qatar, Arabia, and India.

📐 Technical Standards & Parameters

Supported Clean Agent Systems:

Standards Followed:

Key Testing Parameters:

🏢 Facilities We Serve:

Why Choose Manycon for FM200 Room Testing in Saudi ?

Related Images

📞 Book a Duct Test in Saudi Today!

MANYCON TRADING AND CONTRACTING WLL

Manycon Contracting Company Office : 3478 Al Yaqout Road, Ad Dar Al Baida, 6207, Riyadh 1457, Kingdom of Saudi Arabia

MANYCON Saudi– Your Trusted Partner in Passive Fire Protection.

MANYCON – Sealing Leaks. Securing Airflow. Supporting QCD from Duct to Delivery